ANALYTICAL REPORT.

ENV26275 – SE165301

Customer:

Your Reference:

SGS Report Number:

Date of Receipt of Samples:

Date of Sampling:

Wayne Carew Reid

Wall Cladding

ENV 26275 (SE165301)

15th May, 2017

15th to 19th May, 2017

The samples were analysed in accordance with your instructions. The results and associated information are contained in the  following pages of the report. Should you have any queries regarding this report please contact the undersigned.

NATA accreditation file: http://nata.asn.au/index.php/scopeinfo/?key=4354

Reported by:     Dr David Stone

Date:     23/05/2017

Report authorised by:     Dr Peter Novella

Date:     7/06/2017

This document is issued, on the Client’s behalf by the company under its General Conditions of Service available on request and accessible at http://www.sgs.com/terms_and_conditions.htm. The client’s attention is drawn to the limitation of liability, indemnification and jurisdiction issues defined therein.

Any other holder of this document is advised that information contained hereon reflects the company’s findings at the time of its intervention only and within the limits of client’s instructions, if any. The company’s sole responsibility is to its client and this document does not exonerate parties to a transaction from exercising all their rights and obligations under the transaction documents.

This test report shall not be reproduced except in full, without written approval of the laboratory.

Sample Decription:

SE165301

One piece of composite wall cladding (500mm X 360mm)

Division 4.1 Flammable Solids Testing

Flammable Solids (Division 4.1) testing was performed on the composite sample in general accordance with the relevant procedures as defined within the United Nations Manual of Tests and Criteria (UN Manual (OECD, 2009)). Part III – Section 33.2 of the UN Manual (OECD, 2009) defines the procedures for Divison 4.1 Flammable Solids testing.

The procedure prescribes a preliminary screening test be conducted to determine if, on ignition by a gas flame, propagation by burning with flame or smouldering occurs. If propagation occurs within a specified time then the full test is to be carried out to determine the rate and vigour of burning.

If in the screening test the substance did not ignite and propagate combustion either by burning with flame or smouldering, it is not necessary to perform the complete burning rate test as the substance is not a readily combustible solid of Division 4.1. If propagation occurs and burning time was less than a specified time, the full burning rate test is to be performed.

2.1   Test Modifications

The procedure as defined within Part III – Section 33.2 of the United Nations Manuals of Tests and Criteria (OECD, 2009) prescribes that the sample be moulded into a 250mm long x 20mm wide x 10mm heigh triangular train. The material was cut to approximatly 250mm long x 50mm wide, a rectangular shape simulating the size of material tested as powder or cake.

2.2   Testing Criteria

In regards to a sample undergoing a preliminary screening test, Part III – Section 33.2 of the UN Manual (OECD,2009) states that for metals or metal – alloys a hot frame should be applied to one end of the sample train until it ignites or for a maximum of 5 minutes  (if the sample does not ignite). If the substance does not ignite and propagate combustion either by burning with flame or smoulder along 200mm of the sample train then the substance should not be classified as a flammable solid and no further testing is required.

2.3   Results

The composite sample was not considered a Division 4.1 flammable solid as the flame and any combustion was not propagated after removal of an intense flame, in contact initially for 1 minute. Refer to the Photographs below.

Table 1: Preliminary Screening Test Results of Division 4.1 Flammable Solids Tesing

Sample ID Time Flame Was Applied (mins) Flame Propagate ≥200mm? Time Flame Propagate =200mm Result
SE165301 1 No Flame failed to propagate Not 4.1

3.0 References

Organisation for Economic Cooperation and Development (OECD), 2009. Recommendations on the Transport of Dangerous Goods – Manual of Tests and Criteria Fifth Revised Edition, United Nations Publication, Sales No. E.09. VIII.3, ISBN 978-92-1-139135-0, ISSN 1014-7160.

Organisation for Economic Cooperation and Devolopment (OECD), 2013. UN Model Regulations UN Recommendations on the Transport of Dangerous Good – Model Regulations Eighteenth Revised Edition, United Nations Publication, Sales No. E.13.VIII.1 ,ISBN 978-92-1-139146-6, e-ISBN 978-92-1-056081-8, ISSN 1014-5753.

Photograph 1: Division 4.1 Test – prior to commencement of testing.

Photograph 2: Division 4.1 Test – immediately after the commencement of testing, intense flame at far right.

Photograph 3: Division 4.1 Test – 30 seconds after commencement of testing, intense flame at far right.

Photograph 4: Division 4.1 Test – 60 seconds after test commencement, immediately prior to flame removal.

Photograph 5: Division 4.1 Test – 75 seconds after commencement of testing, flame removed about 15 seconds.

Photograph 6: Division 4.1 Test – 90 seconds after commencement of testing, flame removed about 30 seconds.

Photograph 7: Division 4.1 Test – 120 seconds after commencement of testing, flame removed about 60 seconds.